BXUV.D949 Fire Resistance Ratings - ANSI/UL 263 Design/System ...
Steel Floor and Form Units* — Composite 1-1/2, 1-5/8, 2 or 3 in. deep galv units or 4-1/2 in. deep DECK WEST INC — 36 in. wide Type B-DW, Inverted B-DW, BA-DW, Inverted BA- 1.5VL may be fastened together with min 1 in. long No. 12x14 self-drilling, ... Retrieve Full Source

METAL DECK And CONCRETE QUANTITIES - SDI - Steel Deck Institute
1. METAL DECK AND CONCRETE QUANTITIES Richard B. Heagler, P.E Director of Engineering, Nicholas J. Bouras, Inc. A typical steel framed building has composite ... Read Content

Steel Framed Floors
The cost comparison sets the 0.6C form deck or 1.5VL wide rib deck at unity. All percentages are relative to this deck type. non-composite or composite steel joists, non-composite beams (cambered or un-cambered), or composite beams (cambered ... Fetch Full Source

Pictures of 1.5vl Composite Deck

Vulcraft Roof Catalog/REV2
Steel roof and floor deck, composite & non composite floor joists for more information, contact a vulcraft sales office vulcraft manufacturing locations: 1.5vl and 1.5vli 1.5vlr 2vli 3vli notes: 1. * this profile is not available from indiana.. 2. ... Content Retrieval

Composite Steel Joists - Department Of Civil & Environmental ...
1.5VL 2.5 3.97 145 72 26-5/8 CJ-41 20 22.5 2L-1.75x1.75x.188 2L-2.5x2.5x.250 1.5VL 2 deep composite deck. Results from these tests (Easterling, Gibbings, and Murray, 1993) showed close correlation between pushout and full-scale beam tests. ... Read Here

CHAPTER 1 INTRODUCTION - DLA History - About The Scholarly ...
Composite floor systems have been used in buildings for over thirty years (Salmon and Johnson 1996). Composite construction typically consists of a concrete slab in. Vulcraft 1.5VL 22 ga. deck was used in all tests although the concrete slab ... Retrieve Document

G. REVIEW OF LITERATURE - DLA History - About The Scholarly ...
1.5VL Deck 36.00" 6.00" 1.75" 2.50" 1.50" Fig. G.3 Vulcraft Deck Profile Used by Strocchia et al. (1990) 6 Structural steel tee sections (WT 5x11) were used in the first tests as base members. Deck on Composite Beams and Joists, ... Access Full Source


CSJ-53 12 30 ST-2x3.85 2L-2.5x2.5x.212 1.5VL 2 4.40 145 40 12-3/4 CSJ-63 capacity of the test specimens. When 2 or 3 inch (51 or 76 mm) composite deck is utilized, these deck profiles typically have a stiffening rib at the center of each bottom rib. ... Access This Document

Design No. D949
Steel Floor and Form Units* — Composite 1-1/2, 1-5/8, 2 or 3 in. deep galv units or 4-1/2 in. deep welded to deck corrugations. Side joints of Type 1.5VL may be fastened together with min 1 in. long No. 12x14 self-drilling, self-tapping steel screws 36 in. OC max. WIREMOLD CO ... View Full Source

Design No. D788 - Tucker & Mulhern | Home
Welded to deck corrugations. CANAM STEEL CORP — 36 in. wide Type P-3623, P-3606, P-3615 composite; 24 in. wide Type P-2432 composite. DIV OF NUCOR CORP — 24, 30 or 36 in. wide, Types 1.5VL, 1.5VLI, 1.5VLP, 1.5VLR; 24 or 36 in. wide, Types 2VLI, 3VLI, 2VLP, 3VLP. Side joints of Type 1.5VL ... Fetch This Document

Design No. N789 - Building Materials And Specialty ...
Steel Joist or Joist Girder — Composite or noncomposite. Minimum 8K1 steel joist. 30 or 36 in. wide, Types 0.6C, 1.0C, 1.5C, 1.5VLR , 1.5VL, 1.5VLI, 1.5VLP, 24 or 36 in. wide, Types 2VLI, 2VLP, 3VLI, Deck, In. Min Thkns w/Cellular Deck, In. 1 1-1/16 1-1/16 1-1/2 1-3/8 1-3/8 ... Fetch This Document

BXUV.D788 Fire Resistance Ratings - ANSI/UL 263 Design/System ...
Factory welded to deck corrugations. Welded to supports 12 in. OC. through welding P-3606, P-3615 composite; 24 in. wide Type P-2432 composite. 1.5VL may be fastened together with min 1 in. long No. 12x14 self-drilling, ... View Document